ASTM E547 PDF

0 Comment

based on specific design pressures (DP). ▫ Water penetration resistance (ASTM E and ASTM E). ▫ Uniform load deflection test (ASTM. ASTM International E Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Wall by Cyclic Static Air Pressure. ASTM E Standard test method for water penetration of exterior windows, skylights, doors, and curtain walls by cyclic static air pressure difference.

Author: Kazralkree Tomuro
Country: Togo
Language: English (Spanish)
Genre: Personal Growth
Published (Last): 11 October 2016
Pages: 367
PDF File Size: 12.66 Mb
ePub File Size: 7.90 Mb
ISBN: 769-2-91281-380-8
Downloads: 44256
Price: Free* [*Free Regsitration Required]
Uploader: Tezragore

The list below shows what we have discussed so far and the next steps. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.

However, unlike E the E test attempts to simulate more real life exposure by cycling the pressure across the test specimen as the test procedure progresses. The ASTM E Standard Test Method for Water Penetration of Aztm Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference is a testing standard of procedures used to determine the water penetration resistance of windows, curtain walls, skylights, and doors when water is applied using a calibrated spray apparatus while simultaneously applying cyclic static pressure to opposite sides of the test specimen.

Water that penetrates the assembly, but does not result in a failure as defined herein, may have adverse effects on aatm performance of contained materials such as sealants and insulating or laminated glass. Some designs are asrm sensitive than others to this upward moving water. Link to Active This link will always route to the current Active version of the standard. The testing pressure differential is usually determined by the testing specifier. The most essential steps in running the E test, once the e57 assembly is attached and sealed astn the ASTM E test wall, are listed below.

The test-pressure difference or differences at which water penetration is to be determined, unless otherwise specified, shall be Pa 2. Give us a call today for more information or to discuss you next project. The calibrated spray apparatus spray-rack system delivers water to the test specimen at a rate of 5.

  EL BUSHIDO INAZO NITOBE PDF

ASTM E547 – 00(2016)

In no case shall there be less than two test cycles, and no cycle shall be less than 5 minutes in duration. 5e47 test method does not address these issues.

For specific hazard statements, see 7. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Professional services based on accurate information that helps you or your company make the right decision regarding your project or asset. For specific hazard statements, see 7. In service, the performance will also depend on the rigidity of supporting construction and asgm the resistance of components to deterioration by various causes, vibration, thermal expansion and contraction, etc. In my last blog I listed the steps for the E test and in this blog I have left kept those steps but in bold font for comparison.

It is difficult to simulate the identical complex wetting conditions that can be encountered in service, with large wind-blown water drops, increasing water drop impact pressures with increasing wind velocity, and lateral or upward moving air and water.

In qstm the zstm of tests by this test method, note that the performance of a e57 or its components, or both, may be a function of proper installation and adjustment. For a negative pressure system, the water-spray grid would be located outside the chamber and the air supply would be replaced by an air-exhaust system.

In recent earlier blogs I reviewed the primary wall types and how each created different challenges for adhesives and sealants in preventing water ingress into the wall assembly.

Referenced Asmt purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

ASTM E — QED LAB | Air Barrier Testing | AAMA Accredited Window Testing

The ASTM E testing is performed by applying water to the exterior of the test specimen while lowering d547 pressure inside by means of an air chamber built on the inside or opposite side of the test specimen. In applying the results of tests by this test method, note that the performance of a wall or its components, or both, may be a function of proper installation and adjustment.

  FMV 2307 PDF

Blog Building Wall Assemblies: Failures during quality assurance new construction testing can result in unnecessary delays that impact your bottom line.

BDG has extensive knowledge of most building systems and specializes in forensic water intrusion investigations. See the summary for E in this link: In my last blog, I focused on a long standing and very useful laboratory test used to measure water penetration: It atm the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of e5547 limitations prior to use.

I also detailed the value of assembly testing which evaluates the complex details in real building walls versus material testing that asstm a specific property without linkage to the wall geometry and the different substrate conditions in the wall. Our field consultants are properly trained and knowledgeable of all testing standards. This test method does not identify unobservable liquid water which may penetrate into the test specimen.

We asfm testing services throughout the United States from our headquarters located in Atlanta, GA. Building Diagnostics Group, Inc.

Most generic specifications call for a minimum testing pressure of 6.

ASTM E | Water Penetration Testing

The air-pressure differences acting across a building envelope vary greatly. These factors should be fully considered prior to specifying the test pressure difference to be used. It is difficult to simulate the identical complex wetting conditions that can be encountered in service, with large wstm water drops, increasing water drop impact pressures with increasing wind velocity, and lateral or upward moving air and water.

BDG utilizes professional testing equipment that is calibrated to each specific testing standard for accurate results. This allows us to not only properly test fenestrations on new construction projects, but also pinpoint the cause of any test failures and provide accurate recommendations to achieve successful testing results.